Infinity Range Header
Available in Reverse Cycle - 15.8kW, 18.0kW
Refrigerant R410A

Key features

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Connectable Distribution Duct
    Connectable Distributing Duct

    Systems are capable of attaching a field-supplied branch ducts distributing the airflow.

  • Connectable Fresh Air Duct
    Connectable Fresh Air Duct

    Allows introduction of fresh air to the occupied space.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • Fresh Air Intake
    Fresh Air Intake

    Fresh air can be taken in by a fan which can be connected using an external control unit.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

  • Automatic Air Flow Adjustment
    Automatic Air Flow Adjustment

    The micro-processor automatically adjusts the air flow to follow changes in room temperature.

  • Zone Control
    Zone Control

    This function enables efficient air-conditioning by selecting specific zones from the various zones divided within the indoor space.

Download our brochure

Download or view the brochure in a PDF by clicking below

Download PDF

Take control. Controller options.

This range is compatible with the following controller options.

  • controller-feature tick
    Backlit Display

    An illuminated display for improved visibiltiy and clairty. Brightness and light duration can be customised to suit your preferences.

  • controller-feature tick
    Set Temperature Auto Return

    The set temperature automatically returns to the previous set temperature at the touch of a button.

  • controller-feature tick
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

Find the perfect model. Explore the High Static Next Gen range.

Technical Specifications

Attribute ARTG60LDTA 15.80kW(C) 18.00kW(H) View model
Operation Type
Reverse Cycle
Power Source V/Ph/Hz
230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max))
15.80 (6.2 - 16.3)
Heating Capacity kW (Rated (Min - Max))
18.00 (6.2 - 18.5)
Input Power Cooling kW (Rated (Max))
4.92 (6.15)
Input Power Heating kW (Rated (Max))
4.99 (6.18)
EER Cooling kW/kW
3.21
COP Heating kW/kW
3.61
Star Rating Cooling (0-10) (Hot / Average / Cold)
2.5 / 2.5 / 2.5
Star Rating Heating (0-10) (Hot / Average / Cold)
2.5 / 1.5 / 1.0
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.239 / 4.025 / 4.183
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.061 / 3.247 / 2.78
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.508 / 4.594 / 4.902
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.056 / 3.603 / 3.031
Running Current amps (Cooling / Heating)
20.7 / 21.0
Moisture Removal l/hr
2.1
Indoor Sound Pressure Cooling dBA (High / Quiet)
44 / 35
Indoor Sound Pressure Heating dBA (High / Quiet)
44 / 35
Outdoor Sound Pressure dBA (Cooling / Heating)
57 / 59
Outdoor Sound Power dBA
72
Static Pressure Range PA (Min to Max)
60 to 250
Air Circulation (Indoor - High Fan) Cooling l/sec
1139
Air Circulation (Indoor - High Fan) Heating l/sec
1139
Indoor Unit Dimensions mm (Height x Width x Depth)
-
Indoor Unit Weight kg
69.00
Outdoor Unit Dimensions mm (Height x Width x Depth)
1290 x 900 x 330
Outdoor Unit Weight kg
97.00
Piping Connects mm Ø (Liquid / Gas)
9.52 / 15.88
Pipe Length m (Max (Precharged))
75 (30)
Max Height Difference m
30
Operation Range Cooling °CDB (Min to Max)
-15 to 46
Operation Range Heating °CDB (Min to Max)
-15 to 24
Refrigerant Type
R410A
Refrigerant Amount g
4,500
Attribute SET-ARTG65LHTA 18.00kW(C) 20.00kW(H) View model
Operation Type
Reverse Cycle
Power Source V/Ph/Hz
400 / 3 / 50
Cooling Capacity kW (Rated (Min - Max))
18.00 (8.4 - 20.0)
Heating Capacity kW (Rated (Min - Max))
20.00 (7.2 - 22.0)
EER Cooling kW/kW
3.09
COP Heating kW/kW
3.77
Star Rating Cooling (0-10) (Hot / Average / Cold)
2.5 / 2.0 / 2.0
Star Rating Heating (0-10) (Hot / Average / Cold)
3.0 / 2.5 / 2.0
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.121 / 3.816 / 3.936
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.609 / 4.167 / 3.819
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.413 / 4.473 / 4.764
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.614 / 4.348 / 4.036
Moisture Removal l/hr
4.5
Indoor Sound Pressure Cooling dBA (High / Quiet)
45 / 36
Indoor Sound Pressure Heating dBA (High / Quiet)
45 / 36
Outdoor Sound Pressure dBA (Cooling / Heating)
51 / 53
Outdoor Sound Power dBA
70
Static Pressure Range PA (Min to Max)
60 to 200
Air Circulation (Indoor - High Fan) Cooling l/sec
1139
Air Circulation (Indoor - High Fan) Heating l/sec
1139
Indoor Unit Dimensions mm (Height x Width x Depth)
360 x 1400 x 850
Indoor Unit Weight kg
69.00
Outdoor Unit Dimensions mm (Height x Width x Depth)
1428 x 1080 x 480
Outdoor Unit Weight kg
163.00
Piping Connects mm Ø (Liquid / Gas)
12.7 / 25.4
Pipe Length m (Max (Precharged))
75 (30)
Max Height Difference m
30
Operation Range Cooling °CDB (Min to Max)
-15 to 46
Operation Range Heating °CDB (Min to Max)
-15 to 24
Refrigerant Type
R410A
Refrigerant Amount g
5,600

Why Choose Fujitsu

why-choose-fujitsu-warranty 2
Peace of mind

Purchase from a Fujitsu accredited installer and receive a full 6 year warranty.

Explore now
A brand you can trust

Voted by New Zealanders as a trusted brand in the heat pump category.

Explore now

Find where to buy a Fujitsu Heat Pump / Air Conditioner

We have a comprehensive network of Fujitsu Accredited Installers right across New Zealand to ensure that there is a local stockist in your area to assist you wherever you are.

map-icon-white Find a Stockist