Take control. Controller options.
This range is compatible with the following controller options.
Lifestyle Range
This is a wall mounted, energy efficient heat pump / air conditioning unit. A stylish design, along with efficient features like Human Sensor Control and Economy mode have been combined to offer you total control over the comfort of your home.
Type | Split System |
Available in | Reverse Cycle - 2.0kW, 2.5kW, 3.5kW, 4.2kW, 5.0kW, 6.0kW, 7.1kW, 8.5kW, 9.4kW, 9.5kW |
Refrigerant | R32 |
The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
With All DC, electricity loss is decreased and power consumption reduced.
Fine dust, invisible mould spores and harmful microorganisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.
Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.
The auto shut louvres close or open automatically when the unit stops or starts.
The unit automatically switches between operating modes based on the temperature setting and room temperature.
The micro-processor automatically adjusts the air flow to follow changes in room temperature.
The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.
Limits the maximum operation current, and performs operation with the power consumption suppressed.
Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.
Human sensor detects movement of people within the conditioned room.
i-PAM inverter technology enables high output and high efficiency performance.
The filter deodorises by powerfully decomposing absorbed odours using the oxidising and reducing effects of ion generated by the ultra-fine particle ceramic.
The compressor speed and the outdoor unit fan speed are limited to reduce the operational noise.
ON-OFF timer can be set to operate once every 24 hours.
Powerful mode will operate the indoor unit fan and outdoor unit compressor at maximum operation to quickly make the room conditioned and comfortable.
This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.
The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.
The indoor units fan can operate at a low speed to produce quieter operation.
The up/down louvre automatically swings up and down.
v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.
Dust that accumulates on the air conditioner can be easily cleaned with a damp cloth.
Weekly + setback timer can set temperature for two time spans and for each day of the week.
Different ON-OFF times can be set for up to 7 days.
This range is compatible with the following controller options.
The economy operation will save energy in heating, cooling and dry mode and is set by pressing the button on the remote control.
The compressor speed and the outdoor unit fan speed are limited to reduce the operational noise.
The room temperature can be set to go no lower than 10°C, ensuring that the room does not get too cold when not occupied. Perfect for cold climates.
This mode will operate the air conditioner at maximum capacity for 20 minutes, providing comfort faster than ever before.
Different ON-OFF times can be set for up to 7 days.
The room temperature can be set to go no lower than 10°C, ensuring that the room does not get too cold when not occupied. Perfect for cold climates.
With Artificial Intelligence (AI) and based on your air conditioner usage, the app will remind you to clean your filters at certain intervals
Program rules so that your air conditioner turns on automatically once the room goes above or below certain temperatures
Use geolocation to automatically turn your air conditioner on or off based on your proximity to home
For further information on this adapter see here
Attribute | ASTH07KMCD 2.00kW(C) 2.80kW(H) View model | ASTH09KMCD 2.50kW(C) 3.20kW(H) View model | ASTG09KMTC 2.50kW(C) 3.20kW(H) View model | ASTH12KMCD 3.50kW(C) 3.70kW(H) View model | ASTG12KMTC 3.50kW(C) 3.70kW(H) View model | ASTH14KMCD 4.20kW(C) 5.40kW(H) View model | ASTG18KMTC 5.00kW(C) 6.00kW(H) View model | ASTH18KMTD 5.00kW(C) 6.00kW(H) View model | ASTG22KMTC 6.00kW(C) 7.20kW(H) View model | ASTH22KMTD 6.00kW(C) 7.20kW(H) View model | ASTG24KMTC 7.10kW(C) 8.00kW(H) View model | ASTH24KMTD 7.10kW(C) 8.00kW(H) View model | ASTG30KMTC 8.50kW(C) 9.00kW(H) View model | ASTH30KMTD 8.50kW(C) 9.00kW(H) View model | ASTG34KMTC 9.40kW(C) 10.30kW(H) View model | ASTH34KMTD 9.50kW(C) 10.30kW(H) View model |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Operation Type
|
Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle |
Power Source
V/Ph/Hz
|
230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 |
Cooling Capacity
kW (Rated (Min - Max))
|
2.00 (0.9 - 3.5) | 2.50 (0.8 - 3.6) | 2.50 (0.8 - 3.6) | 3.50 (0.8 - 4.1) | 3.50 (0.8 - 4.1) | 4.20 (0.9 - 4.5) | 5.00 (1 - 6.5) | 5.00 (1 - 6.5) | 6.00 (1.1 - 7.5) | 6.00 (1.1 - 7.5) | 7.10 (1.1 - 8.3) | 7.10 (1.1 - 8.3) | 8.50 (2.9 - 10.5) | 8.50 (2.9 - 10.5) | 9.40 (2.9 - 11.2) | 9.50 (2.9 - 11.2) |
Heating Capacity
kW (Rated (Min - Max))
|
2.80 (0.9 - 4.5) | 3.20 (0.9 - 5.3) | 3.20 (0.9 - 5.3) | 3.70 (0.9 - 6.1) | 3.70 (0.9 - 6.1) | 5.40 (0.9 - 6.9) | 6.00 (1.05 - 8.7) | 6.00 (1.05 - 8.7) | 7.20 (1.1 - 9.4) | 7.20 (1.1 - 9.4) | 8.00 (1.1 - 10.1) | 8.00 (1.1 - 10.1) | 9.00 (2.2 - 11.2) | 9.00 (2.7 - 11.2) | 10.30 (2.7 - 11.7) | 10.30 (2.9 - 11.7) |
Input Power Cooling
kW (Rated (Min - Max))
|
0.4 (0.25 - 1.15) | 0.53 (0.15 - 1.04) | 0.53 (0.15 - 1.04) | 0.86 (0.15 - 1.29) | 0.89 (0.15 - 1.29) | 1.15 (0.25 - 1.25) | 1.16 (0.24 - 1.68) | 1.16 (0.24 - 1.93) | 1.58 (0.24 - 2.3) | 1.58 (0.24 - 2.72) | 2.08 (0.24 - 3.15) | 2.08 (0.24 - 3.15) | 2.46 (0.58 - 3.85) | 2.49 (0.6 - 4) | 2.78 (0.59 - 4.03) | 2.72 (0.66 - 4.2) |
Input Power Heating
kW (Rated (Min - Max))
|
0.58 (0.25 - 1.3) | 0.66 (0.25 - 1.61) | 0.66 (0.25 - 1.61) | 0.81 (0.25 - 1.89) | 0.79 (0.25 - 1.89) | 1.4 (0.25 - 2.05) | 1.28 (0.14 - 2.42) | 1.28 (0.14 - 2.75) | 1.7 (0.14 - 2.63) | 1.7 (0.14 - 2.75) | 1.91 (0.14 - 3) | 1.91 (0.14 - 3.17) | 2.34 (0.5 - 4.01) | 2.39 (0.48 - 3.6) | 2.84 (0.6 - 4.24) | 3.04 (0.68 - 3.8) |
EER Cooling
kW/kW
|
5 | 4.71 | 4.71 | 4.07 | 3.93 | 3.65 | 4.31 | 4.31 | 3.8 | 3.8 | 3.41 | 3.41 | 3.45 | 3.41 | 3.38 | 3.49 |
COP Heating
kW/kW
|
4.83 | 4.84 | 4.84 | 4.57 | 4.68 | 3.86 | 4.69 | 4.69 | 4.24 | 4.24 | 4.19 | 4.19 | 3.84 | 3.77 | 3.63 | 3.39 |
Star Rating Cooling
(0-10) (Hot / Average / Cold)
|
5.5 / 5 / 5.5 | 5.5 / 5 / 5.5 | 5.5 / 5 / 5.5 | 5 / 4.5 / 5 | 4.5 / 4.5 / 5 | 4 / 4 / 4 | 4.5 / 4.5 / 4.5 | 5 / 4.5 / 5 | 4 / 4 / 4 | 4.5 / 4 / 4.5 | 3.5 / 3.5 / 3.5 | 3.5 / 3.5 / 3.5 | 3 / 2.5 / 2.5 | 4 / 3.5 / 4 | 3 / 2.5 / 2.5 | 4 / 3.5 / 4 |
Star Rating Heating
(0-10) (Hot / Average / Cold)
|
4 / 3.5 / 3 | 3.5 / 3.5 / 3 | 3.5 / 3 / 3 | 3.5 / 3 / 2.5 | 3.5 / 3 / 2.5 | 3.5 / 2.5 / 2 | 3.0 / 2.5 / 2.5 | 3.5 / 3 / 2.5 | 3 / 2.5 / 2 | 3 / 2.5 / 2 | 3 / 2.5 / 2 | 3 / 2.5 / 2 | 2.5 / 2 / 2 | 4 / 3 / 2 | 2 / 2 / 1.5 | 3.5 / 2.5 / 1.5 |
Total Cooling Seasonal Performance Factor Residential
kW (Hot / Average / Cold)
|
7.296 / 6.734 / 7.007 | 7.193 / 6.68 / 7.049 | 7.219 / 6.755 / 7.155 | 6.545 / 6.108 / 6.521 | 6.477 / 6.193 / 6.625 | 5.834 / 5.513 / 5.926 | 6.46 / 6.102 / 6.472 | 6.652 / 6.3 / 6.726 | 5.852 / 5.558 / 5.943 | 6.009 / 5.714 / 6.146 | 5.307 / 5.039 / 5.4 | 5.344 / 5.094 / 5.481 | 4.658 / 4.334 / 4.477 | 5.56 / 5.284 / 5.716 | 4.628 / 4.317 / 4.482 | 5.501 / 5.242 / 5.633 |
Heating Seasonal Performance Factor Residential
kW (Hot / Average / Cold)
|
5.504 / 5.042 / 4.506 | 5.455 / 5.025 / 4.533 | 5.36 / 4.975 / 4.548 | 5.014 / 4.621 / 4.072 | 5.241 / 4.817 / 4.278 | 5.09 / 4.383 / 3.677 | 4.704 / 4.48 / 4.092 | 5.004 / 4.676 / 4.181 | 4.609 / 4.194 / 3.605 | 4.64 / 4.258 / 3.722 | 4.779 / 4.212 / 3.525 | 4.819 / 4.265 / 3.586 | 4.111 / 3.856 / 3.546 | 5.55 / 4.534 / 3.841 | 3.834 / 3.603 / 3.312 | 5.079 / 4.1 / 3.474 |
Total Cooling Seasonal Performance Factor Commercial
kW (Hot / Average / Cold)
|
8.432 / 9.047 / 10.78 | 8.179 / 8.728 / 10.148 | 8.198 / 8.777 / 10.227 | 7.613 / 8.312 / 10.07 | 7.443 / 8.666 / 10.522 | 6.511 / 6.962 / 7.93 | 7.156 / 7.555 / 8.512 | 7.428 / 7.934 / 9.086 | 6.45 / 6.834 / 7.655 | 6.672 / 7.138 / 8.111 | 5.873 / 6.234 / 7.03 | 5.873 / 6.231 / 6.897 | 5.097 / 5.258 / 5.782 | 6.233 / 6.729 / 7.766 | 5.018 / 5.153 / 5.599 | 6.118 / 6.566 / 7.494 |
Heating Seasonal Performance Factor Commercial
kW (Hot / Average / Cold)
|
5.499 / 5.215 / 4.757 | 5.448 / 5.183 / 4.761 | 5.351 / 5.112 / 4.744 | 5.005 / 4.759 / 4.304 | 5.234 / 4.971 / 4.518 | 5.105 / 4.676 / 4.06 | 4.684 / 4.533 / 4.216 | 4.631 / 4.393 / 4.376 | 4.6 / 4.34 / 3.859 | 4.631 / 4.393 / 3.951 | 4.775 / 4.421 / 3.856 | 4.817 / 4.474 / 3.909 | 4.1 / 3.939 / 3.678 | 5.611 / 5.02 / 4.353 | 3.823 / 3.676 / 3.433 | 5.161 / 4.58 / 3.964 |
Running Current
amps (Cooling / Heating)
|
2.4 / 3.2 | 3 / 3.5 | 3 / 3.5 | 4.2 / 4 | 4.2 / 4 | 5.1 / 6.2 | 5.1 / 5.6 | 5.3 / 5.8 | 6.8 / 7.4 | 7.1 / 7.7 | 8.9 / 8.3 | 9.3 / 8.7 | 10.4 / 10.1 | 11 / 10.6 | 11.7 / 11.9 | 12 / 13.4 |
Moisture Removal
l/hr
|
0.8 | 1 | 0.3 | 1.2 | 1 | 1.6 | 1.3 | 1.3 | 2.3 | 2.3 | 2.7 | 2.7 | 2.5 | 4.4 | 3.5 | 4.9 |
Indoor Sound Pressure Cooling
dBA (High / Quiet)
|
40 / 20 | 40 / 19 | 40 / 19 | 40 / 19 | 40 / 19 | 44 / 20 | 46 / 29 | 46 / 29 | 48 / 29 | 48 / 29 | 49 / 29 | 49 / 29 | 51 / 33 | 51 / 32 | 52 / 34 | 51 / 34 |
Indoor Sound Pressure Heating
dBA (High / Quiet)
|
42 / 22 | 40 / 21 | 40 / 21 | 42 / 21 | 42 / 21 | 45 / 24 | 46 / 29 | 46 / 29 | 48 / 29 | 48 / 29 | 49 / 29 | 49 / 29 | 51 / 33 | 48 / 32 | 51 / 33 | 51 / 33 |
Outdoor Sound Pressure
dBA (Cooling / Heating)
|
50 / 50 | 46 / 46 | 46 / 46 | 49 / 49 | 49 / 49 | 50 / 50 | 47 / 48 | 47 / 49 | 49 / 52 | 49 / 52 | 54 / 52 | 54 / 53 | 50 / 54 | 53 / 55 | 50 / 54 | 58 / 59 |
Outdoor Sound Power
dBA
|
60 | 56 | 55 | 60 | 59 | 65 | 59 | 59 | 61 | 61 | 66 | 66 | 66 | 65 | 65 | 70 |
Air Circulation (Indoor - High Fan) Cooling
l/sec
|
194 | 194 | 194 | 194 | 194 | 214 | 283 | 283 | 294 | 294 | 325 | 325 | 389 | 381 | 389 | 381 |
Air Circulation (Indoor - High Fan) Heating
l/sec
|
217 | 197 | 197 | 214 | 214 | 228 | 283 | 286 | 294 | 300 | 325 | 331 | 389 | 350 | 389 | 372 |
Indoor Unit Dimensions
mm (Height x Width x Depth)
|
270 x 834 x 222 | 270 x 834 x 222 | 270 x 834 x 222 | 270 x 834 x 222 | 270 x 834 x 222 | 270 x 834 x 222 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 340 x 1150 x 280 | 340 x 1150 x 280 | 340 x 1150 x 280 | 340 x 1150 x 280 |
Indoor Unit Weight
kg
|
10.00 | 10.00 | 10.00 | 10.00 | 10.00 | 10.00 | 12.50 | 12.50 | 12.50 | 12.50 | 12.50 | 12.50 | 18.50 | 16.50 | 18.00 | 16.50 |
Outdoor Unit Dimensions
mm (Height x Width x Depth)
|
541 x 663 x 290 | 542 x 799 x 290 | 542 x 799 x 290 | 542 x 799 x 290 | 542 x 799 x 290 | 632 x 799 x 290 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 830 x 900 x 330 | 788 x 940 x 320 | 914 x 970 x 370 | 998 x 940 x 320 |
Outdoor Unit Weight
kg
|
25.00 | 32.00 | 32.00 | 32.00 | 32.00 | 34.00 | 42.00 | 42.00 | 42.00 | 42.00 | 42.00 | 42.00 | 60.00 | 60.00 | 74.00 | 74.00 |
Piping Connects
mm Ø (Liquid / Gas)
|
6.35 / 9.52 | 6.36 / 10.52 | 6.35 / 9.52 | 6.37 / 11.52 | 6.35 / 9.52 | 6.38 / 9.52 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 |
Pipe Length
m (Max (Precharged))
|
20 (15) | 20 (15) | 20 (15) | 20 (15) | 20 (15) | 20 (15) | 30 (15) | 30 (15) | 30 (15) | 30 (15) | 30 (15) | 30 (15) | 75 (20) | 50 (20) | 75 (30) | 50 (25) |
Max Height Difference
m
|
15 | 15 | 15 | 15 | 15 | 15 | 25 | 25 | 25 | 25 | 25 | 25 | 30 | 30 | 30 | 30 |
Operation Range Cooling
°CDB (Min to Max)
|
-10 to 50 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 |
Operation Range Heating
°CDB (Min to Max)
|
-15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 |
Refrigerant Type
|
R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 |
Refrigerant Amount
g
|
700 | 850 | 850 | 850 | 850 | 940 | 1,320 | 1,270 | 1,320 | 1,270 | 1,320 | 1,270 | 1,650 | 1,700 | 2,000 | 2,300 |
Purchase from a Fujitsu accredited installer and receive a full 6 year warranty.
Explore nowVoted by New Zealanders as a trusted brand in the heat pump category.
Explore nowAccess high-level support from our in-house customer care and technical support department.
Find out MoreWe have a comprehensive network of Fujitsu Accredited Installers right across New Zealand to ensure that there is a local stockist in your area to assist you wherever you are.
Find a StockistFujitsu’s Lifestyle range includes a selection of energy efficient heat pump / air conditioners. Wall mounted units offer you flexibility and control over the temperature and air quality inside your home.
Our Lifestyle heat pump / air conditioners combine stylish, contemporary designs with a range of energy saving features that help to control the temperature in your home and improve air quality.
Fujitsu General’s Comfort range of home heat pump / air conditioners are a practical and economical solution to heat and cool your home.
The Lifestyle range includes features like the Apple Catechin Filter and Long-life Ion Deodorisation, which are not available in the Comfort range. Additionally, the Lifestyle range offers Human sensor control as an efficient feature, whereas the Comfort range does not have this capability. Furthermore, the Lifestyle range includes a weekly timer and low noise mode.Lastly, the Lifestyle range offers a 10-degree heat operation, ensuring that the room temperature doesn't drop below this level.
Note: To review further differences between these 2 models, we suggest reviewing the features section in the relevant product brochures for additional detail.
Features of the Fujitsu General Lifestyle Range include a range of inverter technologies that enable high output and high efficiency performance, a Powerful mode to quickly heat or cool the room, and Human Sensor Control technology to save power when the room is not in use.
Lifestyle products are also equipped with weekly and setback timers, to help customise the operation of your heat pump / air conditioner. Fujitsu’s smart heat pump / air conditioners also have an Economy Mode to limit the maximum operation current and reduce energy consumption.
You can find more information on the Fujitsu Lifestyle Range above. There, you can download brochures, view specifications and compare models with one another to help decide which is the best heat pump / air conditioner for your home.
Contact Fujitsu General for more information on installing a new heat pump system in your home.Helpful articles and tips on how to keep your home and office comfortable all year round.