ARTG65LHTA
Product Category High Static Next Gen
Product Range High Static Next Gen range
Capacity 18.00kW Cooling 20.00kW Heating
Model Number SET-ARTG65LHTA

Technical Specifications

Indoor unit ARTG65LHTA
Outdoor unit AOTG65LRLA
Operation Type Reverse Cycle
Power Source V/Ph/Hz 400 / 3 / 50
Cooling Capacity kW (Rated (Min - Max)) 18.00 (8.4 - 20.0)
Heating Capacity kW (Rated (Min - Max)) 20.00 (7.2 - 22.0)
EER Cooling kW/kW 3.09
COP Heating kW/kW 3.77
Star Rating Cooling (0-10) (Hot / Average / Cold) 2.5 / 2.0 / 2.0
Star Rating Heating (0-10) (Hot / Average / Cold) 3.0 / 2.5 / 2.0
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.121 / 3.816 / 3.936
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.609 / 4.167 / 3.819
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.413 / 4.473 / 4.764
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.614 / 4.348 / 4.036
Moisture Removal l/hr 4.5
Indoor Sound Pressure Cooling dBA (High / Quiet) 45 / 36
Indoor Sound Pressure Heating dBA (High / Quiet) 45 / 36
Outdoor Sound Pressure dBA (Cooling / Heating) 51 / 53
Outdoor Sound Power dBA 70
Static Pressure Range PA (Min to Max) 60 to 200
Air Circulation (Indoor - High Fan) Cooling l/sec 1139
Air Circulation (Indoor - High Fan) Heating l/sec 1139
Indoor Unit Dimensions mm (Height x Width x Depth) 360 x 1400 x 850
Indoor Unit Weight kg 69.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 1428 x 1080 x 480
Outdoor Unit Weight kg 163.00
Piping Connects mm Ø (Liquid / Gas) 12.7 / 25.4
Pipe Length m (Max (Precharged)) 75 (30)
Max Height Difference m 30
Operation Range Cooling °CDB (Min to Max) -15 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R410A
Refrigerant Amount g 5,600

Dimensions

What’s included in your purchase

ARTG65LHTA

ARTG65LHTA

Indoor Unit

AOTG65LRLA

AOTG65LRLA

Outdoor Unit

UTY-RVNYN

UTY-RVNYN

Wired Remote Controller - Backlit Wired Controller

Optional Parts

UTY-ANY1

WiFi Control - anywAiR Technology Ducted Controller

UTY-CDPXZC

Zone Control Interface Module - 8 Zones, 24V

UTY-CDPXZD

Zone Control Interface Module - 8 Zones, 240V

UTY-LBTYM

Wireless Remote Controller - Wireless Remote Controller & Infra-Red Receiver Kit

UTY-RHRY

UTY-RHRY

Wired Remote Controller - Simple Controller Without Mode Button

UTY-RNRYZ3

UTY-RNRYZ3

Wired Remote Controller - Backlit Touch Panel Wall Controller

UTY-RSNYN

UTY-RSNYN

Wired Remote Controller - Simple Controller With Mode Button

UTY-XCSX

External Input & Output PCB

UTY-XSZX

Remote Temperature Sensor

UTY-XWZXZ3

External Connect Kit

UTY-XWZXZG

External Connection Wire

WHITE BOX

UTZ-PX1NAB

Drain Pump Kit

Key features

A lightweight and compact design. The indoor unit can be separated for easy installation.

  • Zone Control
    Zone Control

    This function enables efficient air-conditioning by selecting specific zones from the various zones divided within the indoor space.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Connectable Distribution Duct
    Connectable Distributing Duct

    Systems are capable of attaching a field-supplied branch ducts distributing the airflow.

  • Connectable Fresh Air Duct
    Connectable Fresh Air Duct

    Allows introduction of fresh air to the occupied space.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

Operating Manual

Click on the Download button below to get the pdf

Download PDF

This product is part of the Residential and Commercial High Static Next Gen range

Back to Commercial High Static Next Gen range
Get a Fujitsu Air Conditioner

Get a Quote

Find where to buy a Fujitsu General Heat Pump / Air Conditioner

map-icon-white Find a Stockist