ASTG24-30-34LFCC
Product Category Wall Mounted
Product Range Classic range
Capacity 9.20kW Cooling 10.00kW Heating
Model Number ASTG34LFCC
Room Size Large Room

Technical Specifications

Indoor unit ASTG34LFCC
Outdoor unit AOTG34LFTC
Operation Type Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 9.20 (2.9 - 10)
Heating Capacity kW (Rated (Min - Max)) 10.00 (2.7 - 11.2)
Input Power Cooling kW (Rated (Min - Max)) 2.8 (0.59 - 4.4)
Input Power Heating kW (Rated (Min - Max)) 3.03 (0.6 - 4.52)
EER Cooling kW/kW 3.29
COP Heating kW/kW 3.3
Star Rating Cooling (0-10) (Hot / Average / Cold) 3 / 2.5 / 3
Star Rating Heating (0-10) (Hot / Average / Cold) 2 / 1.5 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.756 / 4.417 / 4.619
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 3.522 / 3.307 / 3.051
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.243 / 5.465 / 6.06
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 3.512 / 3.377 / 3.162
Running Current amps (Cooling / Heating) 11.8 / 12.8
Moisture Removal l/hr 3.5
Indoor Sound Pressure Cooling dBA (High / Quiet) 52 / 34
Indoor Sound Pressure Heating dBA (High / Quiet) 52 / 34
Outdoor Sound Pressure dBA (Cooling / Heating) 53 / 53
Outdoor Sound Power dBA 68
Air Circulation (Indoor - High Fan) Cooling l/sec 347
Air Circulation (Indoor - High Fan) Heating l/sec 339
Indoor Unit Dimensions mm (Height x Width x Depth) 320 x 998 x 238
Indoor Unit Weight kg 14.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 1290 x 900 x 330
Outdoor Unit Weight kg 86.00
Piping Connects mm Ø (Liquid / Gas) 9.52 / 15.88
Pipe Length m (Max (Precharged)) 50 (20)
Max Height Difference m 30
Operation Range Cooling °CDB (Min to Max) -10 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R410A
Refrigerant Amount g 2,750

Dimensions

What’s included in your purchase

ASTG24-30-34LFCC

ASTG34LFCC

Indoor Unit

AOTG34LFTC

Outdoor Unit

AR-RAH2E

Wireless Remote Controller

Optional Parts

UTY-RNNYN

UTY-RNNYN

Wired Remote Controller

UTY-RSNYN

UTY-RSNYN

Wired Remote Controller - Simple Controller With Mode Button

UTY-RVNYN

UTY-RVNYN

Wired Remote Controller - Backlit Wired Controller

WHITE BOX

UTY-XWZX

External Connect Kit

Key features

Reliable and trusted comfort featuring inverter technology and a range of features.

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Apple Catechin Filter
    Apple-Catechin Filter

    Fine dust, invisible mould spores and harmful microorganisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Shut Louvre
    Auto Shut Louvre

    The auto shut louvres close or open automatically when the unit stops or starts.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Automatic Air Flow Adjustment
    Automatic Air Flow Adjustment

    The micro-processor automatically adjusts the air flow to follow changes in room temperature.

  • Automatic Louvre
    Automatic Louvre

    The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Double Swing Automatic
    Double Swing Automatic

    Complex swing action of the louvres enables them to swing automatically in both horizontal and vertical directions.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • i-PAM
    i-PAM

    i-PAM inverter technology enables high output and high efficiency performance.

  • Long Life Ion Deodorisation Filter
    Long-Life Ion Deodorisation Filter

    The filter deodorises by powerfully decomposing absorbed odours using the oxidising and reducing effects of ion generated by the ultra-fine particle ceramic.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Right Left Swing
    Right / Left Swing Louvre

    The right/left louvre automatically swings in either direction.

  • Sleep Timer
    Sleep Timer

    The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • Super Quiet Mode
    Super Quiet Mode

    The indoor units fan can operate at a low speed to produce quieter operation.

  • Up Down Swing
    Up/Down Swing Louvre

    The up/down louvre automatically swings up and down.

  • v-PAM
    V-PAM

    v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

  • Washable Panel
    Washable Panel

    Dust that accumulates on the air conditioner can be easily cleaned with a damp cloth.

  • 10 Degree Heat
    10°C Heat Operation

    The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.

Operating Manual

Click on the Download button below to get the pdf

Download PDF

This product is part of the Classic range

Back to Classic range
Get a Fujitsu Air Conditioner

Get a Quote

Find where to buy a Fujitsu General Heat Pump / Air Conditioner

map-icon-white Find a Stockist