Classic Range
Available in Reverse Cycle - 2.5kW, 3.5kW, 4.2kW, 5.0kW, 6.3kW, 7.1kW, 8.0kW, 9.2kW
Refrigerant R410A

Key features

  • 10 Degree Heat
    10°C Heat Operation

    The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Apple Catechin Filter
    Apple-Catechin Filter

    Fine dust, invisible mould spores and harmful microorganisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Shut Louvre
    Auto Shut Louvre

    The auto shut louvres close or open automatically when the unit stops or starts.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Automatic Louvre
    Automatic Louvre

    The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • i-PAM
    i-PAM

    i-PAM inverter technology enables high output and high efficiency performance.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Sleep Timer
    Sleep Timer

    The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • Super Quiet Mode
    Super Quiet Mode

    The indoor units fan can operate at a low speed to produce quieter operation.

  • Up Down Swing
    Up/Down Swing Louvre

    The up/down louvre automatically swings up and down.

  • v-PAM
    V-PAM

    v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

  • Washable Panel
    Washable Panel

    Dust that accumulates on the air conditioner can be easily cleaned with a damp cloth.

  • Weekly Setback Timer
    Weekly + Setback Timer

    Weekly + setback timer can set temperature for two time spans and for each day of the week.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

Download our brochure

Download or view the brochure in a PDF by clicking below

Download PDF

Take control. Controller options.

This range is compatible with the following controller options.

  • controller-feature tick
    Economy Mode

    The economy operation will save energy in heating, cooling and dry mode and is set by pressing the button on the remote control.

  • controller-feature tick
    ON-OFF Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Sleep Timer
    Sleep Timer

    The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • controller-feature tick
    Economy Mode

    The economy operation will save energy in heating, cooling and dry mode and is set by pressing the button on the remote control.

  • Sleep Timer
    Sleep Timer

    The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • controller-feature tick
    10ºC Heat Operation

    The room temperature can be set to go no lower than 10°C, ensuring that the room does not get too cold when not occupied. Perfect for cold climates.

Find the perfect model. Explore the Classic range.

Technical Specifications

Attribute ASTG09LVCC 2.50kW(C) 3.40kW(H) View model ASTG12LVCC 3.50kW(C) 4.80kW(H) View model ASTG14LUCB 4.20kW(C) 5.40kW(H) View model ASTG18LVCC 5.00kW(C) 6.00kW(H) View model ASTG22LVCC 6.30kW(C) 7.20kW(H) View model ASTG24LFCC 7.10kW(C) 8.00kW(H) View model ASTG30LFCC 8.00kW(C) 9.00kW(H) View model ASTG34LFCC 9.20kW(C) 10.00kW(H) View model
Operation Type
Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz
230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max))
2.50 (0.5 - 3.3) 3.50 (0.9 - 4) 4.20 (0.9 - 5.0) 5.00 (0.9 - 5.8) 6.30 (0.9 - 7.3) 7.10 (0.9 - 8.3) 8.00 (2.9 - 9) 9.20 (2.9 - 10)
Heating Capacity kW (Rated (Min - Max))
3.40 (0.5 - 4) 4.80 (0.9 - 5.6) 5.40 (0.9 - 6.0) 6.00 (1.05 - 8.1) 7.20 (1.05 - 8.7) 8.00 (0.9 - 10.6) 9.00 (2.2 - 11) 10.00 (2.7 - 11.2)
Input Power Cooling kW (Rated (Min - Max))
0.58 (0.25 - 1.42) 0.92 (0.25 - 1.42) 1.25 (0.25 - 2.13) 1.53 (0.18 - 2.03) 1.95 (0.18 - 2.75) 2.17 (0.3 - 3.21) 2.42 (0.58 - 4.04) 2.8 (0.59 - 4.4)
Input Power Heating kW (Rated (Min - Max))
0.73 (0.25 - 1.56) 1.11 (0.25 - 2) 1.47 (0.25 - 2.49) 1.49 (0.17 - 3.19) 2.03 (0.17 - 4.18) 2.26 (0.28 - 4.4) 2.64 (0.5 - 4.52) 3.03 (0.6 - 4.52)
EER Cooling kW/kW
4.31 3.8 3.36 3.27 3.23 3.27 3.31 3.29
COP Heating kW/kW
4.66 4.32 3.67 4.03 3.55 3.54 3.41 3.3
Star Rating Cooling (0-10) (Hot / Average / Cold)
4.5 / 3.5 / 3.5 4.5 / 3.5 / 4 3.5 / 3 / 3 4 / 3 / 3.5 3.5 / 3 / 3.5 3 / 3 / 3 3 / 2.5 / 2.5 3 / 2.5 / 3
Star Rating Heating (0-10) (Hot / Average / Cold)
3.5 / 3 / 2.5 3.5 / 3 / 2 3 / 2.5 / 1.5 3.5 / 3 / 2 3 / 2 / 1.5 3 / 2.5 / 1.5 2 / 2 / 1.5 2 / 1.5 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)
6.304 / 5.341 / 5.405 6.172 / 5.388 / 5.629 5.294 / 4.736 / 4.967 5.58 / 4.995 / 5.335 5.149 / 4.789 / 5.119 4.908 / 4.522 / 4.754 4.568 / 4.246 / 4.407 4.756 / 4.417 / 4.619
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)
5.39 / 4.804 / 4.074 5.243 / 4.549 / 3.774 4.796 / 4.013 / 3.345 5.181 / 4.523 / 3.851 4.903 / 3.978 / 3.256 4.717 / 4.035 / 3.393 3.835 / 3.532 / 3.199 3.522 / 3.307 / 3.051
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
7.308 / 7.511 / 8.551 7.113 / 7.462 / 8.566 5.976 / 6.256 / 7.051 6.411 / 6.827 / 7.917 5.69 / 6 / 6.682 5.388 / 5.601 / 6.149 5.011 / 5.179 / 5.711 5.243 / 5.465 / 6.06
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
5.387 / 5.026 / 4.415 5.247 / 4.819 / 4.162 4.808 / 4.347 / 3.629 5.192 / 4.794 / 4.212 4.923 / 4.377 / 3.593 4.732 / 4.318 / 3.758 3.831 / 3.644 / 3.364 3.512 / 3.377 / 3.162
Running Current amps (Cooling / Heating)
2.8 / 3.5 4.2 / 5 5.7 / 6.4 6.5 / 6.3 8.2 / 8.5 9.1 / 9.5 10.2 / 11.1 11.8 / 12.8
Moisture Removal l/hr
1.3 1.8 2.1 2.6 2.7 2.7 3.2 3.5
Indoor Sound Pressure Cooling dBA (High / Low)
- - 45 / 25 - - - - -
Indoor Sound Pressure Cooling dBA (High / Quiet)
41 / 21 42 / 21 - 46 / 29 48 / 32 49 / 32 49 / 33 52 / 34
Indoor Sound Pressure Heating dBA (High / Low)
- - 45 / 27 - - - - -
Indoor Sound Pressure Heating dBA (High / Quiet)
42 / 22 43 / 22 - 46 / 30 48 / 32 48 / 32 49 / 33 52 / 34
Outdoor Sound Pressure dBA (Cooling / Heating)
47 / 47 48 / 48 50 / 50 52 / 53 55 / 56 55 / 56 53 / 55 53 / 53
Outdoor Sound Power dBA
64 66 67 69 72 71 68 68
Air Circulation (Indoor - High Fan) Cooling l/sec
219 225 250 267 267 311 311 347
Air Circulation (Indoor - High Fan) Heating l/sec
225 239 264 267 267 311 319 339
Indoor Unit Dimensions mm (Height x Width x Depth)
293 x 790 x 225 293 x 790 x 225 282 x 870 x 185 293 x 790 x 225 293 x 790 x 225 320 x 998 x 238 320 x 998 x 238 320 x 998 x 238
Indoor Unit Weight kg
9.50 9.50 9.50 9.50 10.00 14.00 14.00 14.00
Outdoor Unit Dimensions mm (Height x Width x Depth)
540 x 660 x 290 540 x 790 x 290 540 x 790 x 290 620 x 790 x 290 620 x 790 x 290 620 x 790 x 290 830 x 900 x 330 1290 x 900 x 330
Outdoor Unit Weight kg
25.00 34.00 38.00 37.00 40.00 41.00 61.00 86.00
Piping Connects mm Ø (Liquid / Gas)
6.35 / 9.52 6.35 / 9.52 6.35 / 12.7 6.35 / 12.7 6.35 / 15.88 6.35 / 15.88 9.52 / 15.88 9.52 / 15.88
Pipe Length m (Max (Precharged))
20 (15) 20 (15) 20 (15) 20 (15) 20 (15) 30 (15) 50 (20) 50 (20)
Max Height Difference m
15 15 15 15 15 20 30 30
Operation Range Cooling °CDB (Min to Max)
-10 to 46 -10 to 46 10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46
Operation Range Heating °CDB (Min to Max)
-15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24
Refrigerant Type
R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant Amount g
850 1,050 1,050 1,450 1,550 1,800 2,100 2,750

Why Choose Fujitsu

why-choose-fujitsu-warranty 2
Peace of mind

Purchase from a Fujitsu accredited installer and receive a full 6 year warranty.

Explore now
A brand you can trust

Voted by New Zealanders as a trusted brand in the heat pump category.

Explore now
Parent-Header-Layout-1376-x-480_NZ_WarrantyInfo_ƒ

Fujitsu General Assist

Access high-level support from our in-house customer care and technical support department.

Find out More

Find where to buy a Fujitsu Heat Pump / Air Conditioner

We have a comprehensive network of Fujitsu Accredited Installers right across New Zealand to ensure that there is a local stockist in your area to assist you wherever you are.

map-icon-white Find a Stockist