Available in Reverse Cycle - 2.5kW, 2.6kW, 3.5kW, 5.0kW, 5.2kW, 7.1kW
Refrigerant R32, R410A

Download our brochure

Download or view the brochure in a PDF by clicking below

Download PDF

Warranty Information

Download our warranty card to read about our 3 year warranty

View Warranty Info

Key features

  • 10 Degree Heat
    10°C Heat Operation

    The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Automatic Louvre
    Automatic Louvre

    The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Demand Response

    This product is designed to be compatible with Air Conditioning Demand Response program. When your electricity supplier activates one of the three modes the air conditioner switches over to the appropriate operation.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Fresh Air Intake
    Fresh Air Intake

    Fresh air can be taken in by a fan which can be connected using an external control unit.

  • i-PAM
    i-PAM

    i-PAM inverter technology enables high output and high efficiency performance.

  • Mildew Resistant Filter
    Mildew Resistant Filter

    The air filter has been treated to resist mildew growth, thus allowing cleaner use and easier care.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Removable Intake Grill
    Removable Intake Grill

    The indoor unit’s intake grille can be removed for easy cleaning and maintenance.

  • Sleep Timer
    Sleep Timer

    The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • Super Quiet Mode
    Super Quiet Mode

    The indoor units fan can operate at a low speed to produce quieter operation.

  • v-PAM
    V-PAM

    v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

  • Washable Panel
    Washable Panel

    Dust that accumulates on the air conditioner can be easily cleaned with a damp cloth.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

  • Weekly Setback Timer
    Weekly + Setback Timer

    Weekly + setback timer can set temperature for two time spans and for each day of the week.

Technical Specifications

Attribute AUTH09KVLA 2.50kW(C) 3.20kW(H) View model AUTG09LVLB 2.60kW(C) 3.50kW(H) View model AUTH12KVLA 3.50kW(C) 4.00kW(H) View model AUTG12LVLB 3.50kW(C) 4.00kW(H) View model AUTH18KVLA 5.00kW(C) 6.00kW(H) View model AUTG18LVLA 5.20kW(C) 6.00kW(H) View model AUTH24KVLA 7.10kW(C) 8.00kW(H) View model AUTG24LVLC 7.10kW(C) 8.00kW(H) View model
Operation Type
Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz
230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max))
2.50 (0.9 - 3.6) 2.60 (0.9 - 3.6) 3.50 (0.9 - 4.1) 3.50 (0.9 - 4.0) 5.00 (0.9 - 5.9) 5.20 (0.9 - 5.9) 7.10 (1.5 - 7.8) 7.10 (2.9 - 8.0)
Heating Capacity kW (Rated (Min - Max))
3.20 (0.9 - 4.5) 3.50 (0.9 - 4.48) 4.00 (0.9 - 5.1) 4.00 (0.9 - 4.83) 6.00 (0.9 - 7.1) 6.00 (0.9 - 7.5) 8.00 (1.4 - 8.4) 8.00 (2.2 - 9.1)
Input Power Cooling kW (Rated (Max))
0.56 (1.13) 0.60 (1.92) 0.9 (1.33) 0.91 (1.99) 1.45 (2.39) 1.56 (1.99) 2.16 (2.72) 2.16 (2.47)
Input Power Heating kW (Rated (Max))
0.76 (1.68) 0.83 (2.28) 1.04 (1.88) 0.98 (2.37) 1.71 (2.78) 1.66 (2.52) 2.21 (2.71) 2.21 (2.8)
EER Cooling kW/kW
4.46 4.33 3.89 3.85 3.45 3.33 3.29 3.29
COP Heating kW/kW
4.21 4.22 3.85 4.08 3.51 3.61 3.62 3.61
Star Rating Cooling (0-10) (Hot / Average / Cold)
4 / 3.5 / 3.5 3.5 / 2.5 / 2.0 3.5 / 3 / 3 3.0 / 2.5 / 2.5 3 / 2.5 / 2.5 3.0 / 2.5 / 2.5 2.5 / 2.5 / 2.5 2.0 / 2.0 / 2.0
Star Rating Heating (0-10) (Hot / Average / Cold)
3.5 / 3 / 2.5 3.0 / 2.5 / 2.0 3 / 2.5 / 2 3.0 / 2.5 / 2.0 3 / 2 / 1.5 2.5 / 2.0 / 1.5 3 / 2.5 / 2 2.5 / 2.0 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)
5.804 / 5.126 / 5.179 5.176 / 4.122 / 3.988 5.206 / 4.74 / 4.862 4.838 / 4.069 / 4.028 4.666 / 4.325 / 4.474 4.556 / 4.127 / 4.241 4.401 / 4.187 / 4.365 3.995 / 3.684 / 3.741
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)
5.064 / 4.575 / 4.108 4.876 / 4.441 / 3.950 4.822 / 4.268 / 3.714 4.774 / 4.284 / 3.701 4.574 / 3.954 / 3.376 4.472 / 3.855 / 3.282 4.58 / 4.044 / 3.533 4.321 / 3.888 / 3.435
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
6.273 / 6.243 / 6.595 5.705 / 5.420 / 5.610 5.599 / 5.651 / 6.011 5.278 / 5.146 / 5.387 5.002 / 5.085 / 5.426 4.917 / 4.973 / 5.298 4.685 / 4.789 / 5.119 4.243 / 4.227 / 4.459
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
5.067 / 4.771 / 4.364 4.873 / 4.607 / 4.190 4.83 / 4.495 / 4.017 4.773 / 4.473 / 3.983 4.586 / 4.21 / 3.709 4.478 / 4.113 / 3.499 4.588 / 4.265 / 3.822 4.322 / 4.059 / 3.674
Running Current amps (Cooling / Heating)
3 / 4 2.9 / 4.1 4.2 / 5 4.3 / 4.7 6.2 / 7.3 6.6 / 7.0 9.6 / 9.7 9.1 / 9.3
Moisture Removal l/hr
0.7 0.5 1.2 0.9 2 2.2 3.4 2.7
Indoor Sound Pressure Cooling dBA (High / Quiet)
33 / 28 33 / 28 37 / 28 37 / 28 38 / 26 38 / 26 49 / 30 49 / 30
Indoor Sound Pressure Heating dBA (High / Quiet)
34 / 27 34 / 27 37 / 28 37 / 28 43 / 30 43 / 30 50 / 33 49 / 33
Outdoor Sound Pressure dBA (Cooling / Heating)
41 / 46 44 / 49 47 / 48 49 / 50 48 / 49 55 / 56 54 / 50 53 / 54
Outdoor Sound Power dBA
59 59 61 62 62 71 69 68
Air Circulation (Indoor - High Fan) Cooling l/sec
150 150 169 169 189 189 258 258
Air Circulation (Indoor - High Fan) Heating l/sec
150 150 169 167 189 222 286 258
Indoor Unit Dimensions mm (Height x Width x Depth)
245 x 570 x 570 245 x 570 x 570 245 x 570 x 570 245 x 570 x 570 245 x 570 x 570 245 x 570 x 570 245 x 570 x 570 245 x 570 x 570
Indoor Unit Weight kg
15.00 15.00 15.00 15.00 15.00 15.00 16.00 16.00
Outdoor Unit Dimensions mm (Height x Width x Depth)
542 x 799 x 290 620 x 790 x 290 542 x 799 x 290 620 x 790 x 290 632 x 799 x 290 620 x 790 x 290 950 x 1030 x 440 830 x 900 x 330
Outdoor Unit Weight kg
32.00 39.00 32.00 39.00 36.00 41.00 62.00 60.00
Grill Dimensions mm (Height x Width x Depth)
49 x 620 x 620 49 x 700 x 700 49 x 620 x 620 49 x 700 x 700 49 x 620 x 620 49 x 700 x 700 49 x 620 x 620 49 x 700 x 700
Grill Weight kg
2.30 2.60 2.30 2.60 2.30 2.60 2.30 2.60
Piping Connects mm Ø (Liquid / Gas)
6.35 / 9.52 6.35 / 9.52 6.35 / 9.52 6.35 / 9.52 6.35 / 12.7 6.35 / 12.7 6.35 / 12.7 6.35 / 15.88
Pipe Length m (Max (Precharged))
20 (15) 20 (15) 20 (15) 20 (15) 30 (20) 30 (15) 30 (30) 30 (20)
Max Height Difference m
15 15 15 15 20 20 30 30
Operation Range Cooling °CDB (Min to Max)
-10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 50 -10 to 46
Operation Range Heating °CDB (Min to Max)
-15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24
Refrigerant Type
R32 R410A R32 R410A R32 R410A R32 R410A
Refrigerant Amount g
850 1,200 850 1,200 1,020 1,650 1,500 2,100

COMMERCIAL CASE STUDIES

Here are a few examples showcasing Fujitsu General's commercial capabilities.

Oasis Shopping Centre

Oasis Shopping Centre

View Case Study
METRO AIR

McDonalds

View Case Study
AUSTRALIAN TURF CLUB

Winx Stand

View Case Study
Glebe Tile
ZENPROP / EPIC AIR

St Josh Street Glebe

View Case Study

This product is part of the Light Commercial type

Back to the Light Commercial type