AUTA30LBLU
Product Category Cassette
Product Range Cassette 4-Way Flow range
Capacity 8.50kW Cooling 10.00kW Heating
Model Number AUTA30LBLU

Technical Specifications

Indoor unit AUTA30LBLU
Outdoor unit AOTA30LGTL
Operation Type Reverse Cycle
Power Source V/Ph/Hz 240 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 8.50 (2.8 - 10.0)
Heating Capacity kW (Rated (Min - Max)) 10.00 (2.7 - 11.2)
Input Power Cooling kW (Rated (Max)) 2.57 (4.04)
Input Power Heating kW (Rated (Max)) 2.77 (4.04)
EER Cooling kW/kW 3.31
COP Heating kW/kW 3.61
Star Rating Cooling (0-10) (Hot / Average / Cold) 2.5 / 2.0 / 2.0
Star Rating Heating (0-10) (Hot / Average / Cold) 3.0 / 2.5 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.216 / 3.874 / 3.956
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.961 / 4.003 / 3.143
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.503 / 4.519 / 4.787
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.980 / 4.371 / 3.624
Running Current amps (Cooling / Heating) 10.8 / 11.6
Moisture Removal l/hr 2.5
Indoor Sound Pressure Cooling dBA (High / Quiet) 40 / 32
Indoor Sound Pressure Heating dBA (High / Quiet) 40 / 32
Outdoor Sound Pressure dBA (Cooling / Heating) 53 / 55
Outdoor Sound Power dBA 69
Air Circulation (Indoor - High Fan) Cooling l/sec 444
Air Circulation (Indoor - High Fan) Heating l/sec 444
Indoor Unit Dimensions mm (Height x Width x Depth) 288 x 840 x 840
Indoor Unit Weight kg 26.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 830 x 900 x 330
Outdoor Unit Weight kg 61.00
Grill Dimensions mm (Height x Width x Depth) 50 x 950 x 950
Grill Weight kg 5.50
Piping Connects mm Ø (Liquid / Gas) 9.52 / 15.88
Pipe Length m (Max (Precharged)) 50 (20)
Max Height Difference m 30
Operation Range Cooling °CDB (Min to Max) -15 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R410A
Refrigerant Amount g 2,100

Dimensions

What’s included in your purchase

AUTA30LBLU

AUTA30LBLU

Indoor Unit

AOTA30LGTL

Outdoor Unit

UTG-UGYA-W

UTG-UGYA-W

Grill

UTB-TUD

UTB-TUD

Wired Remote Controller

Optional Parts

UTY-LRHYA1

UTY-LRHYA1

Wireless Remote Controller - Wireless Remote Controller & Infra-Red Receiver Kit

UTY-RVNYN

UTY-RVNYN

Wired Remote Controller - Backlit Wired Controller

UTD-ECS5A

External Control Wiring Kit

WHITE BOX

UTG-AGYA-W

WHITE BOX

UTG-UGYA-W

WHITE BOX

UTR-YDZC

Air Outlet Shutter Plate

WHITE BOX

UTY-XWZX

External Connect Kit

WHITE BOX

UTZ-KXGA

High Humidity Insulation Kit

WHITE BOX

UTZ-VXGA

Fresh Air Intake Kit

Key features

4-way airflow to suit large open areas. Incorporating the latest fan technology, these units fit neatly into the ceiling and distribute conditioned air through four sides of the unit to achieve optimum room comfort. 

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Shut Louvre
    Auto Shut Louvre

    The auto shut louvres close or open automatically when the unit stops or starts.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Automatic Air Flow Adjustment
    Automatic Air Flow Adjustment

    The micro-processor automatically adjusts the air flow to follow changes in room temperature.

  • Automatic Louvre
    Automatic Louvre

    The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • i-PAM
    i-PAM

    i-PAM inverter technology enables high output and high efficiency performance.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Removable Intake Grill
    Removable Intake Grill

    The indoor unit’s intake grille can be removed for easy cleaning and maintenance.

  • Sleep Timer
    Sleep Timer

    The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • Super Quiet Mode
    Super Quiet Mode

    The indoor units fan can operate at a low speed to produce quieter operation.

  • v-PAM
    V-PAM

    v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

  • Washable Panel
    Washable Panel

    Dust that accumulates on the air conditioner can be easily cleaned with a damp cloth.

  • Weekly Setback Timer
    Weekly + Setback Timer

    Weekly + setback timer can set temperature for two time spans and for each day of the week.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

Operating Manual

Click on the Download button below to get the pdf

Download PDF

This product is part of the Residential and Commercial Cassette 4-Way Flow range

Back to Residential Cassette 4-Way Flow range Back to Commercial Cassette 4-Way Flow range
Get a Fujitsu Air Conditioner

Get a Quote

Find where to buy a Fujitsu General Heat Pump / Air Conditioner

map-icon-white Find a Stockist