Product Category Wall Mounted
Product Range Designer range
Capacity 3.50kW Cooling 4.30kW Heating
Model Number ASTG12KUCA
Room Size Small Room

Technical Specifications

Indoor unit ASTG12KUCA
Outdoor unit AOTG12KUCA
Operation Type Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 3.50 (0.9 - 4.1)
Heating Capacity kW (Rated (Min - Max)) 4.30 (0.9 - 5.7)
Input Power Cooling kW (Rated (Min - Max)) 0.88 (0.25 - 1.38)
Input Power Heating kW (Rated (Min - Max)) 1.06 (0.25 - 1.7)
EER Cooling kW/kW 3.98
COP Heating kW/kW 4.06
Star Rating Cooling (0-10) (Hot / Average / Cold) 4 / 3.5 / 3.5
Star Rating Heating (0-10) (Hot / Average / Cold) 3 / 2.5 / 2
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 5.799 / 5.135 / 5.278
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.501 / 4.12 / 3.628
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 6.566 / 6.807 / 7.666
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.494 / 4.258 / 3.851
Running Current amps (Cooling / Heating) 4.3 / 4.9
Moisture Removal l/hr 1.8
Indoor Sound Pressure Cooling dBA (High / Quiet) 43 / 21
Indoor Sound Pressure Heating dBA (High / Quiet) 43 / 22
Outdoor Sound Pressure dBA (Cooling / Heating) 49 / 49
Outdoor Sound Power dBA 63
Air Circulation (Indoor - High Fan) Cooling l/sec 236
Air Circulation (Indoor - High Fan) Heating l/sec 236
Indoor Unit Dimensions mm (Height x Width x Depth) 282 x 870 x 185
Indoor Unit Weight kg 9.50
Outdoor Unit Dimensions mm (Height x Width x Depth) 540 x 790 x 290
Outdoor Unit Weight kg 34.00
Piping Connects mm Ø (Liquid / Gas) 6.35 / 9.52
Pipe Length m (Max (Precharged)) 20 (20)
Max Height Difference m 15
Operation Range Cooling °CDB (Min to Max) -10 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R32
Refrigerant Amount g 850

Dimensions

What’s included in your purchase

ASTG09-12-18KUCA

ASTG12KUCA

Indoor Unit

AOTG0912KUCA

AOTG12KUCA

Outdoor Unit

AR-REA1E

Wireless Remote Controller

Optional Parts

UTY-RNNYN

UTY-RNNYN

Wired Remote Controller

UTY-RSNYN

UTY-RSNYN

Wired Remote Controller - Simple Controller With Mode Button

UTY-RVNYN

UTY-RVNYN

Wired Remote Controller - Backlit Wired Controller

WHITE BOX

UTY-TWBXF1

Wired Communication Kit

UTY-XWZXZ5

External Control Wiring Kit

Key features

Sleek and slimline design accompanied by efficient and intelligent features.

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Apple Catechin Filter
    Apple-Catechin Filter

    Fine dust, invisible mould spores and harmful microorganisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Shut Louvre
    Auto Shut Louvre

    The auto shut louvres close or open automatically when the unit stops or starts.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Automatic Air Flow Adjustment
    Automatic Air Flow Adjustment

    The micro-processor automatically adjusts the air flow to follow changes in room temperature.

  • Automatic Louvre
    Automatic Louvre

    The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

  • Auto Off Timer
    Auto-Off Timer

    Automatically stops the units operation when a fixed time has elapsed from the start of operation.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • Human Sensor
    Human Sensor

    Human sensor detects movement of people within the conditioned room.

  • i-PAM
    i-PAM

    i-PAM inverter technology enables high output and high efficiency performance.

  • Long Life Ion Deodorisation Filter
    Long-Life Ion Deodorisation Filter

    The filter deodorises by powerfully decomposing absorbed odours using the oxidising and reducing effects of ion generated by the ultra-fine particle ceramic.

  • Low Noise Mode
    Low Noise Mode

    The compressor speed and the outdoor unit fan speed are limited to reduce the operational noise.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Powerful Mode
    Powerful Mode

    Powerful mode will operate the indoor unit fan and outdoor unit compressor at maximum operation to quickly make the room conditioned and comfortable.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Sleep Timer
    Sleep Timer

    The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • Super Quiet Mode
    Super Quiet Mode

    The indoor units fan can operate at a low speed to produce quieter operation.

  • Up Down Swing
    Up/Down Swing Louvre

    The up/down louvre automatically swings up and down.

  • v-PAM
    V-PAM

    v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

  • Washable Panel
    Washable Panel

    Dust that accumulates on the air conditioner can be easily cleaned with a damp cloth.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

  • 10 Degree Heat
    10°C Heat Operation

    The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.