ARTG45LHTA
Product Category High Static Single Phase - Compact
Product Range High Static Single Phase - Compact range
Capacity 11.50kW Cooling 14.00kW Heating
Model Number ARTG45LHTAC

Technical Specifications

Indoor unit ARTG45LHTA
Outdoor unit AOTG45LBTC
Operation Type Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 11.50 (5.7 - 13.5)
Heating Capacity kW (Rated (Min - Max)) 14.00 (6.0 - 15.5)
Input Power Cooling kW (Rated (Max)) 3.70 (5.62)
Input Power Heating kW (Rated (Max)) 3.84 (5.62)
EER Cooling kW/kW 3.11
COP Heating kW/kW 3.65
Star Rating Cooling (0-10) (Hot / Average / Cold) 2.5 / 2.0 / 2.5
Star Rating Heating (0-10) (Hot / Average / Cold) 3.0 / 2.0 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.250 / 3.979 / 4.140
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.581 / 3.875 / 3.249
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.550 / 4.647 / 4.970
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.588 / 4.174 / 3.508
Running Current amps (Cooling / Heating) 15.5 / 16.1
Moisture Removal l/hr 0.9
Indoor Sound Pressure Cooling dBA (High / Low) 43 / 35
Indoor Sound Pressure Heating dBA (High / Low) 43 / 35
Outdoor Sound Pressure dBA (Cooling / Heating) 58 / 58
Outdoor Sound Power dBA 72
Static Pressure Range PA (Min to Max) 60 to 260
Air Circulation (Indoor - High Fan) Cooling l/sec 903
Air Circulation (Indoor - High Fan) Heating l/sec 903
Indoor Unit Dimensions mm (Height x Width x Depth) 425 x 1250 x 490
Indoor Unit Weight kg 54.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 914 x 970 x 370
Outdoor Unit Weight kg 75.00
Piping Connects mm Ø (Liquid / Gas) 9.52 / 15.88
Pipe Length m (Max (Precharged)) 50 (20)
Max Height Difference m 30
Operation Range Cooling °CDB (Min to Max) -15 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Amount g 2,900

Dimensions

What’s included in your purchase

ARTG45LHTA

ARTG45LHTA

Indoor Unit

AOTG45LBTC

Outdoor Unit

UTY-RVNYN

UTY-RVNYN

Wired Remote Controller - Backlit Wired Controller

Optional Parts

UTY-ANY1

WiFi Control - anywAiR Technology Ducted Controller

UTY-CDPXZC

Zone Control Interface Module - 8 Zones, 24V

UTY-CDPXZD

Zone Control Interface Module - 8 Zones, 240V

UTY-RNNYN

UTY-RNNYN

Wired Remote Controller

UTY-RSNYN

UTY-RSNYN

Wired Remote Controller - Simple Controller With Mode Button

UTD-ECS5A

External Control Wiring Kit

UTY-XWZXZ3

External Connect Kit

Key features

A compact size and lightweight indoor unit. High static air conditioning allows for an increased number of air ducts to be installed and the single phase power allows greater installation flexibility.

  • Zone Control
    Zone Control

    This function enables efficient air-conditioning by selecting specific zones from the various zones divided within the indoor space.

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Connectable Distribution Duct
    Connectable Distributing Duct

    Systems are capable of attaching a field-supplied branch ducts distributing the airflow.

  • Connectable Fresh Air Duct
    Connectable Fresh Air Duct

    Allows introduction of fresh air to the occupied space.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

Operating Manual

Click on the Download button below to get the pdf

Download PDF

This product is part of the High Static Single Phase - Compact range

Back to High Static Single Phase - Compact range