Product Category | Multi Systems |
Product Range | Wall Mounted Classic Range |
Capacity Class | 2.50 kW |
Model Number | ASTG09LVCC |
Room Size | Small Room |
Operation Type | Reverse Cycle |
Power Source V/Ph/Hz | 230 / 1 / 50 |
Capacity Class kW | 2.5 |
Running Current amps (Cooling / Heating) | 0.14 / 0.14 |
Indoor Sound Pressure Cooling dBA (High / Quiet) | 36 / 23 |
Indoor Sound Pressure Heating dBA (High / Quiet) | 36 / 23 |
Air Circulation (Indoor - High Fan) Cooling l/sec | 178 |
Air Circulation (Indoor - High Fan) Heating l/sec | 178 |
Indoor Unit Dimensions mm (Height x Width x Depth) | 293 x 790 x 225 |
Indoor Unit Weight kg | 9.50 |
Piping Connects mm Ø (Liquid / Gas) | 6.35 / 9.52 |
Operation Range Cooling °CDB (Min to Max) | 18 to 32 |
Operation Range Heating °CDB (Min to Max) | 16 to 30 |
Refrigerant Type | R410A |
Available in six capacity sizes, this range of wall mounted indoor units are suitable for all areas of your home ranging from small to large sized rooms.
With All DC, electricity loss is decreased and power consumption reduced.
Fine dust, invisible mould spores and harmful microorganisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.
Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.
The auto shut louvres close or open automatically when the unit stops or starts.
The unit automatically switches between operating modes based on the temperature setting and room temperature.
The micro-processor automatically adjusts the air flow to follow changes in room temperature.
The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.
This product is designed to be compatible with Air Conditioning Demand Response program. When your electricity supplier activates one of the three modes the air conditioner switches over to the appropriate operation.
Limits the maximum operation current, and performs operation with the power consumption suppressed.
Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.
i-PAM inverter technology enables high output and high efficiency performance.
The filter deodorises by powerfully decomposing absorbed odours using the oxidising and reducing effects of ion generated by the ultra-fine particle ceramic.
ON-OFF timer can be set to operate once every 24 hours.
This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.
The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.
The indoor units fan can operate at a low speed to produce quieter operation.
The up/down louvre automatically swings up and down.
v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.
Dust that accumulates on the air conditioner can be easily cleaned with a damp cloth.
Weekly + setback timer can set temperature for two time spans and for each day of the week.
Different ON-OFF times can be set for up to 7 days.
The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.