Under Ceiling Console
Available in Reverse Cycle - 10.0kW, 12.5kW, 13.8kW
Refrigerant R410A

Warranty Information

Download our warranty card to read about our 3 year warranty

View Warranty Info

Key features

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Automatic Air Flow Adjustment
    Automatic Air Flow Adjustment

    The micro-processor automatically adjusts the air flow to follow changes in room temperature.

  • Automatic Louvre
    Automatic Louvre

    The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Demand Response

    This product is designed to be compatible with Air Conditioning Demand Response program. When your electricity supplier activates one of the three modes the air conditioner switches over to the appropriate operation.

  • Double Swing Automatic
    Double Swing Automatic

    Complex swing action of the louvres enables them to swing automatically in both horizontal and vertical directions.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • i-PAM
    i-PAM

    i-PAM inverter technology enables high output and high efficiency performance.

  • Mildew Resistant Filter
    Mildew Resistant Filter

    The air filter has been treated to resist mildew growth, thus allowing cleaner use and easier care.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Right Left Swing
    Right / Left Swing Louvre

    The right/left louvre automatically swings in either direction.

  • Sleep Timer
    Sleep Timer

    The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • Up Down Swing
    Up/Down Swing Louvre

    The up/down louvre automatically swings up and down.

  • v-PAM
    V-PAM

    v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

Technical Specifications

Attribute ABTA36LAT 10.00kW(C) 11.20kW(H) View model ABTA45LAT 12.50kW(C) 14.00kW(H) View model ABTG54LRTA 13.80kW(C) 16.00kW(H) View model
Operation Type
Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz
230 / 1 / 50 230 / 1 / 50 400 / 3 / 50
Cooling Capacity kW (Rated (Min - Max))
10.00 (3.8 - 11.2) 12.50 (4.0 - 13.3) 13.80 (5.4 - 16.0)
Heating Capacity kW (Rated (Min - Max))
11.20 (4.0 - 14.0) 14.00 (4.2 - 15.5) 16.00 (5.8 - 18.0)
Input Power Cooling kW (Rated (Max))
3.11 (4.54) 3.56 (4.9) 4.34 (6.72)
Input Power Heating kW (Rated (Max))
3.02 (4.54) 4.11 (4.9) 4.67 (6.72)
EER Cooling kW/kW
3.21 3.23 3.18
COP Heating kW/kW
3.71 3.41 3.43
Star Rating Cooling (0-10) (Hot / Average / Cold)
2.5 / 2.5 / 2.5 2.5 / 2.5 / 2.5 2.5 / 2.0 / 2.5
Star Rating Heating (0-10) (Hot / Average / Cold)
2.5 / 2.0 / 1.5 2.5 / 2.0 / 1.5 2.5 / 2.0 / 1.0
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.461 / 4.132 / 4.293 4.404 / 4.103 / 4.259 4.259 / 3.907 / 4.020
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.469 / 3.985 / 3.466 4.417 / 3.686 / 3.082 4.216 / 3.551 / 2.977
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.795 / 4.894 / 5.237 4.720 / 4.811 / 5.141 4.573 / 4.626 / 4.925
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.472 / 4.178 / 3.737 4.428 / 3.837 / 3.348 4.221 / 3.677 / 3.225
Running Current amps (Cooling / Heating)
13.0 / 12.7 14.9 / 17.2 6.2 / 6.6
Moisture Removal l/hr
3.0 4.0 5.0
Indoor Sound Pressure Cooling dBA (High / Quiet)
47 / 32 49 / 34 51 / 38
Indoor Sound Pressure Heating dBA (High / Quiet)
47 / 32 49 / 34 51 / 38
Outdoor Sound Pressure dBA (Cooling / Heating)
54 / 54 55 / 55 55 / 56
Outdoor Sound Power dBA
68 69 70
Air Circulation (Indoor - High Fan) Cooling l/sec
528 583 639
Air Circulation (Indoor - High Fan) Heating l/sec
528 583 639
Indoor Unit Dimensions mm (Height x Width x Depth)
240 x 1660 x 700 240 x 1660 x 700 240 x 1660 x 700
Indoor Unit Weight kg
46.00 46.00 48.00
Outdoor Unit Dimensions mm (Height x Width x Depth)
1290 x 900 x 330 1290 x 900 x 330 1290 x 900 x 330
Outdoor Unit Weight kg
86.00 86.00 104.00
Piping Connects mm Ø (Liquid / Gas)
9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Pipe Length m (Max (Precharged))
50 (20) 50 (20) 75 (30)
Max Height Difference m
30 30 30
Operation Range Cooling °CDB (Min to Max)
-15 to 46 -15 to 46 -15 to 46
Operation Range Heating °CDB (Min to Max)
-15 to 24 -15 to 24 -15 to 24
Refrigerant Type
R410A R410A R410A
Refrigerant Amount g
3,350 3,350 3,450

COMMERCIAL CASE STUDIES

Here are a few examples showcasing Fujitsu General's commercial capabilities.

AUSTRALIAN TURF CLUB

Winx Stand

View Case Study
Oasis Shopping Centre

Oasis Shopping Centre

View Case Study
METRO AIR

McDonalds

View Case Study
Glebe Tile
ZENPROP / EPIC AIR

St Josh Street Glebe

View Case Study

This product is part of the Light Commercial type

Back to the Light Commercial type