Mid Static Slimline R32
Available in Reverse Cycle - 5.0kW, 7.1kW, 8.5kW, 10.0kW, 12.5kW, 13.0kW
Refrigerant R32

Key features

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • 46 IN-BUILT SAFETY TRAY
    In-Built Safety Tray

    The safety tray and drain port is in-built into the system.

  • Demo Mode

    This function allows the indoor unit to be operated alone at exhibitions and showrooms.

  • Operating Temperature Range 50°C

    The maximum guaranteed operating temperature range to 50 degrees in cooling mode.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • Demand Response

    This product is designed to be compatible with Air Conditioning Demand Response program. When your electricity supplier activates one of the three modes the air conditioner switches over to the appropriate operation.

  • Connectable Fresh Air Duct
    Connectable Fresh Air Duct

    Allows introduction of fresh air to the occupied space.

  • Connectable Distribution Duct
    Connectable Distributing Duct

    Systems are capable of attaching a field-supplied branch ducts distributing the airflow.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Zone Control
    Zone Control

    This function enables efficient air-conditioning by selecting specific zones from the various zones divided within the indoor space.

Download our brochure

Download or view the brochure in a PDF by clicking below

Download PDF

Find the perfect model. Explore the Mid Static Slimline R32 range.

Technical Specifications

Attribute ARTH18KMTAP 5.00kW(C) 6.00kW(H) View model ARTH24KMTAP 7.10kW(C) 8.00kW(H) View model ARTH30KMTAP 8.50kW(C) 10.00kW(H) View model ARTH36KMTAP 10.00kW(C) 11.20kW(H) View model ARTH45KMTAP 12.50kW(C) 14.00kW(H) View model ARTH54KMTAP 13.00kW(C) 15.00kW(H) View model
Operation Type
Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz
230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max))
5.00 (0.9 - 6.4) 7.10 (1.8 - 8.1) 8.50 (2.8 - 10.3) 10.00 (2.8 - 11.4) 12.50 (4 - 14) 13.00 (4.5 - 15)
Heating Capacity kW (Rated (Min - Max))
6.00 (0.9 - 7.8) 8.00 (2 - 9.1) 10.00 (2.7 - 11.3) 11.20 (2.7 - 14) 14.00 (4.2 - 16.5) 15.00 (4.7 - 18)
Input Power Cooling kW (Rated (Max))
1.37 (1.95) 2.15 (2.92) 2.6 (4.28) 3.23 (4.3) 4 (5.18) 4.31 (5.19)
Input Power Heating kW (Rated (Max))
1.58 (2.39) 2.19 (2.67) 2.62 (4.44) 3.3 (4.5) 4 (5.22) 4.45 (5.23)
EER Cooling kW/kW
3.65 3.3 3.5461 3.1914 3.13 3.02
COP Heating kW/kW
3.8 3.65 4.1151 3.7299 3.5 3.37
Star Rating Cooling (0-10) (Hot / Average / Cold)
3 / 2.5 / 2 3 / 2 / 1.5 2.5 / 2.5 / 2.5 2.5 / 2.5 / 2.5 3 / 2 / 1.5 2.5 / 2 / 1.5
Star Rating Heating (0-10) (Hot / Average / Cold)
3.5 / 3 / 3 3 / 2.5 / 2.5 3 / 2.5 / 2 3 / 2 / 1.5 2.5 / 2.5 / 3 2.5 / 2.5 / 2.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)
5.012 / 4.663 / 4.844 4.558 / 4.294 / 4.484 4.781 / 4.91 / 5.264 4.338 / 4.141 / 4.359 4.462 / 4.265 / 4.509 4.354 / 4.163 / 4.412
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.74 / 4.182 / 3.616 4.694 / 3.996 / 3.375 5.036 / 4.472 / 3.899 4.568 / 3.815 / 3.201 4.512 / 3.881 / 3.295 4.371 / 3.688 / 3.113
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
5.377 / 5.485 / 5.866 4.878 / 4.999 / 5.356 4.781 / 4.91 / 5.264 4.635 / 4.781 / 5.14 4.775 / 4.943 / 5.327 4.664 / 4.837 / 5.221
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.747 / 4.409 / 3.923 4.704 / 4.291 / 3.622 4.731 / 4.361 / 3.834 4.583 / 4.139 / 3.467 4.522 / 4.129 / 3.641 4.382 / 3.98 / 3.356
Running Current amps (Cooling / Heating)
5.9 / 6.8 9.1 / 9.2 11 / 11.2 13.6 / 13.9 16.8 / 16.8 18.1 / 18.7
Moisture Removal l/hr
1.3 1.7 1.6 2.9 4.5 5
Indoor Sound Pressure Cooling dBA (High / Quiet)
33 / 23 38 / 27 38 / 28 38 / 27 40 / 29 40 / 29
Indoor Sound Pressure Heating dBA (High / Quiet)
33 / 23 38 / 27 38 / 28 38 / 27 40 / 29 40 / 29
Outdoor Sound Pressure dBA (Cooling / Heating)
48 / 49 48 / 50 51 / 53 53 / 53 55 / 57 55 / 57
Outdoor Sound Power dBA
62 68 69 70 71 72
Static Pressure Range PA (Min to Max)
50 to 150 50 to 150 50 to 150 50 to 150 50 to 150 50 to 150
Air Circulation (Indoor - High Fan) Cooling l/sec
300 416.67 541.67 575 600 600
Air Circulation (Indoor - High Fan) Heating l/sec
300 416.67 541.67 575 600 600
Indoor Unit Dimensions mm (Height x Width x Depth)
240 x 1000 x 700 240 x 1000 x 700 240 x 1400 x 700 240 x 1400 x 700 240 x 1400 x 700 240 x 1400 x 700
Indoor Unit Weight kg
32.00 32.00 42.00 42.00 42.00 42.00
Outdoor Unit Dimensions mm (Height x Width x Depth)
632 x 799 x 290 716 x 820 x 315 788 x 940 x 320 788 x 940 x 320 998 x 940 x 320 998 x 940 x 320
Outdoor Unit Weight kg
36.00 36.00 52.00 52.00 67.00 67.00
Piping Connects mm Ø (Liquid / Gas)
6.35 / 12.7 6.35 / 12.7 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Pipe Length m (Max (Precharged))
30 (20) 30 (20) 50 (30) 50 (30) 50 (30) 50 (30)
Max Height Difference m
20 25 30 30 30 30
Operation Range Cooling °CDB (Min to Max)
-10 to 50 -10 to 50 -10 to 50 -10 to 50 -10 to 50 -10 to 50
Operation Range Heating °CDB (Min to Max)
-15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24
Refrigerant Type
R32 R32 R32 R32 R32 R32
Refrigerant Amount g
1,020 1,250 1,900 1,900 2,700 2,700

Why Choose Fujitsu

why-choose-fujitsu-warranty 2
Peace of mind

Purchase from a Fujitsu accredited installer and receive a full 6 year warranty.

Explore now
A brand you can trust

Voted by New Zealanders as a trusted brand in the heat pump category.

Explore now

Find where to buy a Fujitsu Heat Pump / Air Conditioner

We have a comprehensive network of Fujitsu Accredited Installers right across New Zealand to ensure that there is a local stockist in your area to assist you wherever you are.

map-icon-white Find a Stockist